Pool Size and Equipment Calculator

For Rectangle/Square style Pools

Use this handy form to see what you may need in the future, or should have now. To run this form you will need to have a Java capable browser, with java enabled.

Simply enter in the variables and click the calculate button. The Turnover is the number of hours that it will take for the entire body of water to pass through the filter system. Commercial pools are designed to a minimum of 6 hours, while a residential pool can be up to 12. In general, the faster the turnover the better the water.

As for the filter area differences, 12 - 15 gpm per sq.ft. is for a commercial application. 20 gpm is used for a lot of residential pools and is generally the maximum flowrate through a filter. The lower the flowrate, the better the water will filter. We still need to attain the 15 gpm/sq.ft. to properly backwash the sand filter.

Enter the length of the Pool in feet.

Rectangular Pool

We also need to know the Width in feet.

Enter the Average Depth in feet.

Turnover in hours- how long to filter all the water
Enter below in ° F for Boiler selection

Ambient Air Temperature

Desired Pool Temperature

Volume
(usg)
Surface Area
(sq.ft.)
Flowrate
(usgpm)
Sand Filter
(sq.ft.)@15usgpm
Sand Filter
(sq.ft)20@usgpm
Cartridge
(sq.ft.)@1usgpm
D.E. Filter
(sq.ft) @ 2usgpm
Below is the Boiler selection, based on 1° - 1¼°F temperature rise and 3½ mph ave. wind
Minimum suggested Boiler size is BTU's

For most applications a sand filter will serve you better. On a pool or fountain a cartridge filter will plug up much too quickly. D.E. (diatomaceous earth) filters are mainly used on large commercial pools where a high flowrate is required but there is insufficient room for sand filters. D.E. filtration systems have smaller footprints than same sized sand filters.

The Boilers must be derated by 10% for installations over 2000'. To get a 1½° Temperature rise, increase boiler size bu 50%. For 2° Temperature rise. increase BTU's by 75%. Derate for Propane gas as follows: Models 334-824 by 6%. Models 962-1826 by 8%. Models 2100-4001 do not need to be derated. This information is specific to our RayPak Boilers.

Now aside from any automatic chemical feeders etc. you may want to install, an Ozone system might be something you have considered. Below are the figures for a commercially designed system. A water body other than a public pool will be very successful with this system, but can be substantially reduced and still derive great benefits. These numbers are for a slipstream system, based on total filtered water . The tanks are oversized 30% to allow for the fact that we have not yet found a tank that is 100% efficient. The 1.5 ppm figure is what you might size a Spa or very heavy use system at. More on this in the Ozone section. Go check out the Ion section to see how you can round out your system very nicely.

*Note* - 1 mg/l = 1 ppm = 1 gr/m3 = 1gr/264.2 usg

O3 System
Flow usgpm
@ 30%
Contact Tank
Size usg
Dosage Rate
Grams/hour
@ 1 ppm
Dosage Rate
Grams/hour
@ 1.5 ppm
2 minute Contact
4 minute Contact